CG260 Gas Generator Set

US
Metric

Overview

Generator Set Specifications

Maximum Continuous Rating
3333 / 3000 ekW @1.0pf
Fuel Type
Natural Gas, Coal Gas
Maximum Electrical Efficiency
43.90%
Frequency
50Hz / 60 Hz
RPM
1000 / 900 rpm

Engine Specifications

Engine Model
CG260-12
Displacement
12443.00 in³
203.90 l
Aspiration
TA
Bore
10.20 in
260.00 mm
Stroke
12.60 in
320.00 mm

Generator Set Dimensions

Length
315.00 in
8000.00 mm
Width
105.00 in
2660.00 mm
Height
110.00 in
2794.00 mm
Dry Weight - Genset
89617.00 lb
40649.60 kg
Features

High Reliability

  • Anti-knock control and cylinder balancing protect the engine from overload and ensure reliable operation
  • State-of-the-art turbocharger A140 with Wastegate ensures full performance even under high temperatures and higher altitudes
  • Higher reliability and lower maintenance costs due to open combustion chamber technology

High Availability, High Profitability

  • Miller valve timing and optimized compression ratios ensure high efficiency and low fuels costs
  • More profit for your plant
  • Long maintenance intervals and general overhaul only after 80,000 oh allow an operation of 10 years without general overhaul
  • Flexible fields of application also with fluctuating gas qualities due to Total Electronic Management (TEM)

Optimized Lubrication Consumption

  • Savings of up to 4,000 liters of lube oil per year compared to comparable gensets
  • Improved components reduce lube oil consumption
  • Lower operating costs due to 30% lower lube oil consumption in comparison to similar products
Standard Equipment
  • Air Inlet
    • One-element single-stage air cleaner with enclosure and sevice indicator
    • Turbocharger with a water-cooled bearing case for all cylinder
  • Control Panels
    • TEM (Total Electronic Management)
  • Cooling
    • flange connections for JW inlet and outlet
    • Jacket water and SCAC thermostats
    • Electrical jacket water and aftercooler coolant pump
  • Exhaust
    • Exhaust waste gate for the CG260-12
    • Closed crankcase ventilation system
  • Fuel system
    • Independently controlled cylinder monitoring and ignition system
    • Electronic fuel metering valve
    • Pre-chamber spark plugs
  • Generator
    • Busbar connections
    • Closed-coupled generator result in no torque transmission to the base frame
    • Anti-condensation space heater
    • Reactive droop
    • 3-phase sensing and KVAR/PF control
    • Grid code generator
    • Winding temperature detectors
  • Starting/Charging
    • Compressed air engine start
  • General
    • Crankshaft vibration damper and guard
Optional Equipment
  • Cooling
    • CHP skid